BLOGS

Focusing on the latest research and development achievements of Ti:radium, exploring new milestones in the development of artificial intelligence and robotics industries, and sharing with you the infinite possibilities of cutting-edge technology.

The Hole Through the Middle: How Humanoid Joints Route Power and Data Through the Axis
2026-10-26
The Hole Through the Middle: How Humanoid Joints Route Power and Data Through the Axis

Every cable in a humanoid has to cross a joint to reach the motor beyond it — and the cleanest way across is straight through the middle of the actuator itself. This article walks through the quiet geometry behind that choice: how big the hole actually is, what it costs, why modern joints need only four wires, and how cable torsion decides whether the wiring outlives the robot.

Ask an engineer what limits a humanoid robot's reach and you will hear about torque density, gear ratios, battery chemistry. You will rarely hear about the hole. Yet inside every rotary joint of a modern humanoid runs a hollow bore — a clear passage along the rotation axis — and through that passage passes everything the joints beyond it need to live: battery power and a communication bus.

The size of that hole, and what the cable does inside it, is one of the quieter constraints in joint design. Get it wrong and the wiring becomes the first thing to fail; get it right and the whole body simplifies, one conductor at a time.

Why the Cable Goes Down the Middle

Put a cable on the rotation axis of a joint and it only ever twists. Move it 30 mm off the axis and every swing of the joint also bends it, stretches it and drags it across whatever is nearby. Industrial robot arms live with the second problem: they wear external dress packs and cable guides on the outside of the arm, and those dress packs still wear out.

A humanoid has no room for any of that. A loop of cable at the shoulder snags on shelving, catches on people and gets pinched when the elbow folds flat against the torso. So the standard answer is a hollow-shaft actuator: a frameless motor whose rotor sits on a tube, a reducer with a clear bore through its centre, an encoder that reads around the hole rather than across it, and an output flange with a matching opening. The wiring for everything downstream passes through the joint like thread through a bead.

Unitree's G1 humanoid is the textbook case. A teardown by the harness maker JONVER found that all motor power and signal cables run through the centre of the joint shafts, with the motors in each limb connected in series through internal channels. Power arrives on a unified XT30 connector and data travels on CAN. (Source: JONVER teardown, 2026.)

The Bore Is a Budget

A hole in the middle of a joint is not free. The reducer's wave generator, the motor rotor and the output bearing all have to grow around it, so a hollow unit carries more metal at a larger radius than a solid-shaft unit of the same torque.

The trade is easy to see in Harmonic Drive's catalog, the closest thing the industry has to a reference design. Across the SHG-2UH hollow-shaft range, the through-bore holds steady at roughly a third of the outside diameter — from a 20 mm bore at 70 mm OD in size 14, up to a 38 mm bore at 110 mm OD in size 25. Ratio-50 units in that range carry rated torques from 7 N·m to 51 N·m. The share matters more than the absolute numbers: a wrist-sized joint around 70 mm across leaves you about 20 mm of bore; a hip-sized one can offer close to 40 mm.

Frameless motor makers design for the same space. Kollmorgen's TBM2G series, pitched at robot joints, offers rotor inner diameters from about 25 mm in the 50 mm frame up to 57.5 mm in the 115 mm frame, explicitly to pass "encoders, cables, hoses, shafts, tools."

Those industrial reference units are also heavier than what goes into a production humanoid. A size-14 SHG-2UH reducer alone weighs 0.71 kg — for comparison, a teardown of Unitree's G1 put a whole small joint actuator, motor plus reducer plus drive electronics plus housing, at roughly 525 g. Production humanoids use lighter custom-integrated modules, and that gap is exactly the space integrated-joint vendors compete in.

Joint swingFree cable lengthTwist per metre
±90°0.25 m360°/m
±90°0.30 m300°/m
±135°0.30 m450°/m
±135°0.375 m360°/m
±180°0.50 m360°/m

*Table: twist arithmetic for a cable clamped at both ends. The rating of the cable, not the space in the housing, sets the minimum free length.*

Four Wires, Not Forty

Twenty millimetres is plenty for a thin bundle and hopeless for a fat one. What keeps the bundle thin is the network, not the mechanics. Each joint on a modern humanoid carries its own servo drive, so the cable crossing a joint does not need three motor phases and an encoder lead for every actuator further out. It needs a shared DC supply and a shared bus.

Menlo's open-source Asimov humanoid shows how far that goes. Every actuator has two electrically identical XT30 (2+2) ports carrying exactly four conductors: battery positive, battery negative, CAN high and CAN low. The actuators daisy-chain along six physical branches into the torso — two hips, two shoulders, the waist and the neck. The cost of sharing one supply is voltage sag when several joints pull peak current at once, as they do on a jump landing; the G1 answers that with distributed capacitor buffers at the supply end of the outermost joints, according to the JONVER teardown.

Buses with more bandwidth add conductors and shielding, which is one more reason bore size and network choice get decided together. EtherCAT's cabling is thicker than CAN's; a single-pair physical layer goes further still — we covered what single-pair communication buys a joint stack in our earlier article on AUTBUS going into the joint.

Rule of thumb: the number of conductors crossing a joint is a systems decision. Centralised drive architectures multiply it; distributed joint drives with a shared DC bus hold it to a handful. If your joint module needs more than a few wires through the bore, the wiring architecture is the problem, not the hole.

Twist, Not Bend

A cable through a hollow shaft is clamped at both ends — one on the fixed side, one on the part that moves. When the joint swings, the length between the clamps twists. It does not rub, but it does fatigue, and the fatigue depends on how much twist each metre of cable has to absorb.

Industrial cable makers rate this directly. In July 2026, igus launched the CFROBOT8.PLUS robot bus cable family — covering CAN, Ethernet up to CAT7, PROFINET and DeviceNet — rated for ±360° of torsion per metre of free cable (with a 1 m free length under specified temperature and speed conditions), designed for 10 million cycles and tested past 15 million. Those figures come from six-axis industrial robots, not humanoids, but the arithmetic transfers.

A joint that swings ±135° with 0.3 m of free cable between clamps loads that cable at ±450° per metre — beyond the rating. Stretching the free length to 0.375 m brings it back to ±360°/m. In a compact forearm, the fix is often routing the cable through two joints in one run so the twist is shared between them.

That is why free length is a design parameter, not packaging slack. Shorten it to save space and every cycle costs more of the cable's life.

Chinese joint-module vendors have been converging on the same answer from the production side: at CIIF 2026 in Shanghai, Leaderdrive showed a full-size range of joint modules — vendors claim positioning precision of 20 arc-seconds, a 15,000-hour working life and 500-microsecond real-time communication — built around hollow routing "for convenient series wiring", with IP67 sealing demonstrated underwater at the booth. When multiple vendors standardise on the same routing pattern, it has stopped being an option and become table stakes. (Source: gongkong and Chinese industry media reports, October 2026; figures are vendor claims.)

When the Joint Never Stops: Slip Rings

Twisting works as long as the joint has end stops. Take the stops away and no cable survives. Boston Dynamics did exactly that with electric Atlas: of its 56 degrees of freedom, most joints can rotate continuously, and both the head and the waist turn all the way round so the robot can work behind itself without stepping. How the company carries power and data across those continuously rotating joints is, as of October 2026, not public — and it is the hardest wiring problem in the body.

The usual tool is a slip ring: rotating contacts that pass current across a spinning interface. Industrial options already cover what a humanoid needs. Mercotac's liquid-metal contact rings pass up to 30 A on six of the eight circuits of its Model 830, with the remaining two rated 4 A. For data, ROTOCON markets brushless EtherCAT slip rings listed with the EtherCAT Technology Group, claiming zero packet loss in rotation. Supplier Servotecnica lists the problems that remain for humanoid joints — size, weight, wear, electrical noise, power handling and cost — and each one grows with the number of circuits. That is one more argument for four-wire buses: every conductor you remove from the joint crossing is a conductor the slip ring never has to carry.

What to Check Before You Commit to a Joint Module

The bore, the bus and the cable read together as one specification. Five checks cover most of it:

  • Clear bore through the whole stack — motor, reducer, encoder, brake and flange. The smallest hole in the chain sets the limit, and brakes and connector retainers shrink it further.
  • Conductors per joint crossing. Local drives on a shared DC bus and CAN or a single-pair bus keep it to a handful; centralised architectures multiply it.
  • Joint range against free cable length. Compute degrees of twist per metre and compare with the cable's torsion rating — remember the ±135°/0.3 m example that exceeds a ±360°/m cable.
  • Connector serviceability. Atlas builds joints as swappable modules; open-source designs like Asimov thread cables through several joints before they are joined. The routing pattern decides how fast a joint can be replaced in the field.
  • Continuous rotation. Any joint without end stops needs a slip ring or a contactless link, with its own mass, noise and lifetime budget.

At Ti5ROBOT we see the same arithmetic from the module side: every conductor and connector you can move inside the integrated joint housing is one less thing crossing the bore, one less failure mode, and one fewer reason to disassemble the arm. The same logic drives how we specify encoder and feedback layouts — see our analysis of dual encoders and the joint accuracy ceiling — and how modules such as the Lightweight Joint Module series and the Humanoid Robot Actuator line are specified as complete joints rather than loose parts. The hole through the middle is not a packaging detail — it is the budget that the whole wiring architecture spends.

The Quiet Constraint, Made Explicit

None of this shows up on a torque-density chart. But the hollow bore determines how the limbs get wired, the bus choice determines how thick the bundle is, and the cable's torsion rating determines how long the robot lives between harness failures. The joints that survive ten million swings are the ones whose designers treated the hole as a first-class specification — on par with torque, ratio and mass.

The next time a joint module datasheet lists a "through-bore" figure, read it the way an accountant reads a line of credit: it is not the size of the hole, it is the size of everything you will never have to route around it.

Source: humanoid.guide, "Hollow-shaft joints: how power and data get through every humanoid joint" (October 2026); igus press release on CFROBOT8.PLUS (July 2026); JONVER Unitree G1 teardown (2026); Menlo Asimov electrical documentation (2026); Boston Dynamics electric Atlas CES 2026 announcement; Harmonic Drive SHF/SHG catalog; gongkong CIIF 2026 joint-module coverage (October 2026); Kollmorgen TBM2G frameless motor specifications.